MinInventoryInterval

FlexNet Manager Suite 2022 R1 (On-Premises)

Command line | Registry

MinInventoryInterval specifies the minimum interval (in hours) between collections of inventory. FlexNet inventory agent will not generate or upload inventory if it is invoked less than this period of time after the most recent inventory generation. This preference controls the collection of inventory by the FlexNet inventory agent as well as through zero footprint inventory collection.

The time of the last inventory generation is determined from the last modified time of the most recently cached inventory file, typically stored under Application Data\ManageSoft Corp\ManageSoft\Tracker\Inventories\ on the inventory device.
Tip: Since this integer value is specified in hours, it is not possible to specify 30 minutes, which is the maximum period allowed for hardware inventory checking (and uploading where values are changed) when FlexNet Manager Suite is used as a replacement for ILMT for calculating sub-capacity license consumption. In that case, it is necessary to preserve the default value of zero hours minimum.

Values

Values / range

Any non-negative integer.

Default value

0

Example values

24

Command line

Tool

Inventory component (ndtrack)

Example

-o MinInventoryInterval=24

Generates inventory at most once per day

Registry

Installed by

Code internals, or manual configuration

Computer preference

[Registry]\ManageSoft\Tracker\CurrentVersion

FlexNet Manager Suite (On-Premises)

2022 R1