Error -9029: MsiDriverPackages Table

AdminStudio 2023 | 25.0 | Automated Application Converter / App-V Assistant / ThinApp Assistant / Citrix Assistant

The following table documents this message:

Error -9029: MsiDriverPackages Table

Category

Description

Type:

Error

Message:

The conversion process does not support data in the MSI table 'MsiDriverPackages'.

Cause:

You encounter this error when the Windows Installer package that you are converting includes a MsiDriverPackages table. During the conversion process, the MsiDriverPackages table is not read.

Resolution:

The MsiDriverPackages table includes one record for each driver package component in the application.

Citrix XenApp does not support any type of driver. For example, when installing a printer, you can install the printer software within the isolation environment, but not the printer drivers.

Therefore, to resolve this issue, you need to install any required drivers outside of the isolation environment on the user desktop machines.