Error -4313: Failed to access the package

AdminStudio 2023 | 25.0 | Automated Application Converter

The following table documents this message:

Error -4313: Failed to access the package

Category

Description

Message:

Error -4313 processing package: Failed to access the package

Cause:

The Automated Application Converter could not read from the package source location or could not write to the package cache location.

Resolution:

To resolve this error, try the following:

Ensure that the host machine has access to the network and is visible to/accessible from the virtual machine (if it is running on a different computer).
Verify that the Guest Username and Guest Password properties on the Machines tab for the virtual machine are set correctly.
If the package is on a network share, verify that both the host machine and virtual machine have access to that network share.
Verify that the virtual machine’s Setup Cache Path property on the Machines tab for this virtual machine is set to a drive on the virtual machine, especially if the virtual machine does not have a C: drive.
Verify that the package does not already exist as read-only.