Storage

Flexera recommends that Software Vulnerability Manager On-Premises Edition system is installed on storage that is failure tolerant in the first or second level. If you do not use a failure tolerant hardware RAID, it is recommended that you define a software RAID-1 during installation. Please ensure that your RAID hardware is compatible with your Red Hat version.

Flexera recommends the following partitioning best practice:

The root partition “/” should be at least 100GB.
The boot partition “/boot” should be at least 100MB.
The swap partition is based on the amount of RAM that currently is available.

Alternatively, you can use the layout that Red Hat Enterprise Linux installation suggests.

Important:Configure the correct host name and network interfaces during installation.

Select Customize software packages to be installed and remove this selection from all application groups. Failure to do so will install additional unrequired software.
Ensure that you have adequate disk space for the MYSQL/mariaDB databases (by default stored in /var/lib/mysql).