Hardware_Model_Power.csv
Column Position |
Column Name |
Type |
Column Description |
1 |
HardwareModelPowerID |
UUID |
The unique identifier for hardware model power. |
2 |
HardwareModelID |
UUID |
The HardwareModelID in Technopedia this Hardware Model Power record relates to. |
3 |
ACCurrentHighMin |
Float |
Manufacturer's suggested AC electrical input requirements: The minimum current when the voltage switch is turned on to the high range setting. |
4 |
ACCurrentHighMax |
Float |
Manufacturer's suggested AC electrical input requirements: The maximum current when the voltage switch is turned on the high range setting. |
5 |
ACCurrentLowMin |
Float |
Manufacturer's suggested AC electrical input requirements: The minimum current when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range). |
6 |
ACCurrentLowMax |
Float |
Manufacturer's suggested AC electrical input requirements: The maximum current when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range). |
7 |
ACFrequencyMin |
Float |
The manufacturer's suggested AC input requirements: The minimum frequency (whether the voltage switch is turned on low/high or when the device has no voltage switch). |
8 |
ACFrequencyMax |
Float |
The manufacturer's suggested AC input requirements: The maximum frequency (whether the voltage switch is turned on low/high or when the device has no voltage switch). |
9 |
ACHeatDissipationAverage |
String |
The average amount of heat per-unit of time generated by the device during typical use when it is hooked up to AC power (in BTU/hr). |
10 |
ACHeatDissipationMax |
String |
The peak or maximum amount of heat per-units of time generated by the device during typical usage when it is hooked up to AC power (in BTU/hr). |
11 |
ACPhase |
Int64 |
The phase of the AC. |
12 |
AcPowerAverage |
String |
The average amount of power (energy per-unit of time) consumed by the device during typical use when it is hooked up to AC power (in watt or volt-amp). |
13 |
ACPowerAverageUnit |
String |
The unit for AC_POWER_AVG column (watt or volt-amp). |
14 |
ACPowerMax |
String |
The peak or maximum amount of power (energy per-unit of time) consumed by the device when it is hooked up to AC power (in watt or volt-amp). |
15 |
ACPowerMaxUnit |
String |
The unit for the AC_POWER_MAX column (watt or volt-amp). |
16 |
ACVoltageHighMin |
Float |
Manufacturer's suggested AC electrical input requirements: The minimum voltage when the voltage switch is turned to on the high range setting. |
17 |
ACVoltageHighMax |
Float |
Manufacturer's suggested AC electrical input requirements: The maximum voltage when the voltage switch is turned on to the high range setting. |
18 |
ACVoltageLowMin |
Float |
Manufacturer's suggested AC electrical input requirements: The minimum voltage when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range). |
19 |
ACVoltageLowMax |
Float |
Manufacturer's suggested AC electrical input requirements: The maximum voltage when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range) . |
20 |
BatteryLife |
Int64 |
Hours of possible battery life. |
21 |
BatteryType |
String |
Battery type. |
22 |
DCCurrentLow |
Float |
The manufacturer's suggested DC input requirements: The current when the voltage switch is turned on the low setting or when the device has no voltage switch (single voltage). |
23 |
DCCurrentHigh |
Float |
The manufacturer's suggested DC input requirements: The current when the voltage switch is turned on the high setting. |
24 |
DCHeatDissipationAverage |
String |
The average amount of heat per-unit of time generated by the device during typical use when it is hooked up to DC power (in BTU/hr). |
25 |
DCHeatDissipationMax |
String |
The peak or maximum amount of heat per-unit of time generated by the device when it is hooked up to DC power (in BTU/hr). |
26 |
DCPowerAverage |
String |
The average amount of power (energy per-unit of time) consumed by the device during typical use when it is hooked up. |
27 |
DCPowerMax |
String |
The peak or maximum amount of power (energy per-unit of time) consumed by the device when it is hooked up to DC power (in watt or volt-amp). |
28 |
DCVoltageLow |
Float |
The manufacturer's suggested DC input requirements: The voltage when the voltage switch is turned on the low setting or when the device has no voltage switch (single voltage). |
29 |
DCVoltageHigh |
Float |
The manufacturer's suggested DC input requirement: The voltage when the voltage switch is turned on the high setting. |
30 |
EmergencyPower |
String |
Listing of the emergency power. |
31 |
Epeat |
String |
This is a flag to indicate which EPEAT certification the device has earned: Gold, Silver, or Bronze. |
32 |
HasDedicatedCircuit |
String |
Listing of the dedicated circuit. |
33 |
IsEnergyStar |
String |
This is a flag to indicate whether the device has earned the Energy Star certification or not. |
34 |
NonOperatingHumidityMin |
Float |
The manufacturer's suggested minimum humidity (percentage) of the device when it is non-operational or in storage. |
35 |
NonOperatingHumidityMax |
Float |
The manufacturer's suggested peak or maximum humidity (percentage) of the device when it is non-operational or in storage. |
36 |
NonOperatingTemperatureMin |
Float |
The manufacturer's suggested minimum temperature of the device when it is non-operational or in storage (in Fahrenheit). |
37 |
NonOperatingTemperatureMax |
Float |
The manufacturer's suggested peak or maximum temperature of the device when it is non-operational or in storage (in Fahrenheit). |
38 |
OperatingHumidityMin |
Float |
The manufacturer's suggested minimum humidity (percentage) of the device during operation. |
39 |
OperatingHumidityMax |
Float |
The manufacturer's suggested peak or maximum humidity (percentage) of the device during operation. |
40 |
OperatingTemperatureMin |
Float |
The manufacturer's suggested minimum temperature of the device during operation (in Fahrenheit). |
41 |
OperatingTemperatureMax |
Float |
The manufacturer's suggested peak or maximum temperature of the device during operation (in Fahrenheit). |
42 |
PlugType |
String |
Plug type (NEMA). |
43 |
PowerRating |
String |
The summary of the device's various power ratings: Voltage, Frequency, and Current. |
44 |
CreatedDate |
String |
The date when an entry was first created. |
45 |
OrgID |
String |
The unique identifier for the organization. |