IT Asset Management
        (Cloud) 
        The controls in the IBM reporting and archiving
                    settings
                section allow you to use FlexNet inventory for sub-capacity licensing calculations,
                potentially in place of ILMT.
            Remarque : This IBM reporting and archiving
                    settings
                section of the Inventory Settings page
                is available only when you have licensed the FlexNet Manager for Datacenters
                product.
            
        To configure higher frequency processing for IBM PVU or VPC
                licenses:
- 
                Select the Enable frequent hardware scanning for IBM sub-capacity
                    license calculations check
                    box.
                A number of additional controls appear when this check box is selected
                    (provided that the prerequisites described in  Sub-Capacity Licensing Using IBM PVU or IBM VPC have been satisfied).
                         Conseil : In contrast, if you clear this check box, you must either
                        use full capacity calculations for your IBM PVU licenses, or rely on the
                        points calculations collected from ILMT, TAD4D, SUA, or IBM Big Fix.
                        Selecting the check box is a requirement for IBM acceptance of sub-capacity
                        calculations based on FlexNet inventory. 
Saving this page with this
                    check box enabled also has the following effects: 
                        - Modifies the appearance of the Compliance tab on
                            all IBM PVU and IBM VPC licenses so that they can display the peak
                            consumption of sub-capacity points (and the date when this occurred) for
                            each IBM region, together with the full consumption for any devices not
                            eligible for sub-capacity calculations (see Compliance Tab)
- Enables the mapping of enterprise group locations to the three mandatory
                            IBM regions, allowing you to assign ownership of devices to appropriate
                            locations so that their consumption points are directed to the
                            appropriate IBM region (see Locations)
- Causes display of an IBM region column in
                            appropriate searches and listings, such as the Ownership tab on device properties, the Locations page,
                            and the Consumption tab on license
                            properties
- Adds the Serveurs vCenter ou OVM Manager connus target to the list of targets available to collect inventory from
                            VMware vCenter or Oracle VM Manager servers, visible in the Discovery and Inventory Rules page
- Adds the All devices consuming IBM PVU
                    points target to the list of targets available for IBM sub-capacity-related
                            hardware scans, visible in the Discovery and Inventory Rules page
- Enables remote scans by appropriate inventory beacons of all known
                            VMware vCenter and Oracle VM Manager (OVM) servers
- Enables frequent hardware scanning of all target inventory devices where
                            the agent d'inventaire FlexNet is locally installed, as required by IBM
                            (this setting is distributed within policy to the installed agent d'inventaire FlexNets through the inventory beacons, which in turn
                            receive it through the BIBMPVUEnableScanning=truesetting in the BeaconSettings.xml file)
- Enables the recalculation (retrospectively covering the data retention
                            period, including the current reporting period for reports to IBM) of
                            the peak points consumption for each mandatory IBM region (this happens
                            as part of each full license reconciliation process, by default
                            scheduled overnight) 
- Prevents IBM PVU licenses incorporating any points imported from ILMT,
                            where this remains available as an auxiliary inventory source.Conseil : When imports are still available from ILMT, and
                                high-frequency scanning is enabled, there is a report provided that
                                compares the current sub-capacity results imported from ILMT with
                                those calculated by IT Asset Management.
                                
                             
 
- 
                 In the Perform extra inventory scanning every
                            time-interval drop-down list, choose one
                    of the available intervals (between 30 minutes and
                        4 hours).
                The default value ( 30 minutes) is mandatory if
                    you wish to use FlexNet inventory for sub-capacity license calculations in place
                    of an IBM tool such as ILMT (which also captures snapshots for its licensing
                    history every 30 minutes). If you choose an option other than the
                         30 minutes default, a warning appears, allowing
                    you to confirm that your choice is well-informed and intentional. Be aware
                        that this time interval applies not only to the inventory gathering from the
                        host server, but also to the upload of any inventory changes, and import to
                        the inventory database. Recalculation of peak consumption per region, which
                        takes into account any hardware or VM changes that have been imported since
                        the last calculation, occurs as part of the full compliance calculations, by
                        default scheduled overnight.  
- 
                Typically, you will select the Collecter l'inventaire des serveurs VMware vCenter et Oracle VM Manager check
                    box except for exceptional circumstances.
                These servers, identified automatically from the list of discovered devices,
                    are automatically inventoried by the appropriate  inventory beacon remotely
                    accessing their management APIs to track the movement of virtual machines.
                         Remarque : This functionality requires that the virtual host and the inventory beacon can connect across an IPv4 network. (IT Asset Management does not currently support any form of remote execution
                        using IPv6 address families, and therefore a virtual host in an IPv6 zone
                        remains invisible to this functionality.)  
The effects of the check
                    box are as follows: 
                        - When this check box is selected, a drop-down list is exposed that
                            includes the pre-existing target Serveurs vCenter ou OVM Manager connus, along with any custom targets that you have created (details about
                            making selections are in the next step). The default automated target is
                            updated daily to contain all servers (in IPv4 networks) where either
                            VMware vCenter or Oracle VM Manager has been discovered. While the
                            target is active (that is, while this check box is set and the selection
                            saved in the drop-down), those servers are scanned for high-level
                            hardware information, including which virtual machines are running on
                            which host server, using direct inventory gathering by the appropriate
                                inventory beacon.Remarque : While VMs on VMware vCenter are
                                candidates for sub-capacity license consumption, VMs on Oracle VM
                                Manager are always calculated at full consumption. This is because
                                currently IBM accepts Oracle VM servers only on SPARC and UltraSPARC
                                architectures for sub-capacity consumption (and not on x86
                                platforms), and IT Asset Management supports Oracle VM servers
                                only on x86 platforms. 
- When this check box is cleared, high-frequency scans of servers running
                            VMware vCenter or Oracle VM Manager do not occur. In general, you should
                            not clear this check box in production, and the option is available only
                            for exceptional circumstances (for example, while you are waiting for
                            approval from your Oracle team to run the inventory scans). In
                            production, you might clear the check box if your enterprise uses
                            neither of these virtualization products; or if you know that there are
                            no IBM PVU licenses applying on any of the virtual machines managed by
                            these servers (and if you do clear this check box, skip ahead to step
                                6).
                            Otherwise, clearing the check box risks puts you at risk of breaching
                            IBM's conditions, which normally require tracking the movement of
                            virtual machines where the relevant software may be operating.
 
- 
                In the drop-down list to Collecter l'inventaire des serveurs VMware vCenter et Oracle VM Manager, choose
                    your first target for increased scanning.
                Normally you will choose the built-in target for  Serveurs vCenter ou OVM Manager connus. This
                    target, automatically updated after each discovery import, lists all vCenter and
                    OVM virtual management servers. Independently of this setting, you may choose to
                    create a separate custom target to target sub-set of VMware vCenter or Oracle VM
                    Manager servers that you want to scan. Conseil : When the selected target
                        is present in the closed list, it is included in data saved when you click
                            Save on the entire page.  
- 
                If you want to include another target that you have defined, click the
                        + button to the right of the list.
                A new line appears below your previous choice, and you can repeat the
                    selection process for other targets you have defined (as discussed
                    above). 
- 
                In the drop-down list to Enable frequent hardware scans by installed
                    inventory agents within the following targets,
                    choose the first of your existing targets for increased scanning.
                Normally you will choose the built-in target for  All devices consuming IBM PVU
                    points
                    (available only after you have selected the  check
                    box).  Conseil : Despite the name of this built-in target, it in fact
                        includes all devices consuming for both IBM PVU and IBM VPC license types,
                        and is automatically updated after each full inventory import (by default,
                        daily). These computers must have the agent d'inventaire FlexNet installed.
                     
Independently of this setting, you may either: 
                        - Manage the installation and configuration of the agent d'inventaire FlexNet
                            using your preferred deployment technology (this third-party deployment
                            is mandatory in networks using the IPv6 address family); or
- Create a separate rule for discovery and adoption, for which you define
                            the target to match the machines where you want the agent d'inventaire FlexNet installed (this applies only in networks using the
                            IPv4 address family). In this case, the inventory beacon
                            checks for a prior installation on each target machine, and if it is not
                            present, automatically installs agent d'inventaire FlexNet in line with
                            your targeting.
 Conseil : When the selected target is present in the closed list, it
                        is included in data saved when you click Save on the
                        entire page.  
- 
                If you want to include another target that you have defined, click the
                        + button to the right of the list.
                A new line appears below your previous choice, and you can repeat the
                    selection process for other targets you have defined (as discussed
                    above). 
- 
                Click Save (in the bottom right of the page). 
            
Your system is now configured for the more frequent inventory checks required for
                sub-capacity licensing calculations using the agent d'inventaire FlexNet.
            If you have multiple inventory sources, ensure that data from other sources cannot
                overwrite data from the high-frequency inventory you have just enabled. To do
                    this:
                    - Go to the Data Imports page.
- Select the Inventory Data
                        tab.
- Check that the IT Asset Management —
                            Flexera source currently displays
                            Primary (on the right end), and if not,
                        click Make primary.
You may also wish to check the configuration on your IBM PVU and VPC licenses around
                rights on virtual machines and hosts, set in the Use rights & rules tab of
                each license's properties (see Rights on Virtual Machines and Hosts). These are
                already correctly configured if you have set up these licenses using the bibliothèque des droits d'utilisation du produit (Product Use Rights Library) enabled by the FlexNet Manager for Datacenters license term.
        
       
    
IT Asset Management (Cloud)
    
Current