AdminStudio Enterprise Server 11.5 | Job Manager
Edition: Job Manager is included with AdminStudio Enterprise Edition.
From the Manage Application Catalogs View of Job Manager Engine, you can Pause, Shutdown, and Restart Jobs in an Application Catalog:
Button |
Action That is Taken by Job Manager Engine |
Pause |
Click to pause the execution of the Jobs in the selected Application Catalog. Clicking the Pause button tells Job Manager Engine not to start the execution of any new Jobs in the selected Application Catalog, but allow all currently executing jobs to complete normally. Job Manager Engine remains fully aware of the Application Catalog, but does not use any CPU resources to run any Jobs. Therefore, the Pause operation could be used by someone to temporarily give another Application Catalog better access to system resources so that it could complete its jobs faster. When you select a Paused Application Catalog and click Run/Restart, its Pending Jobs begin executing immediately. |
Shutdown |
Click to stop all Jobs on the selected Application Catalog. Any currently running Job Step is allowed to finish, but no additional Jobs will execute. Clicking Shutdown tells Job Manager Engine to fail any currently running Jobs and to unload itself from memory. All resources used by Job Manager Engine for this Application Catalog are freed. When you select a Shutdown Application Catalog and click Run/Restart, the restart operation will need to relaunch and initiate the background thread for the Application Catalog, and therefore a Shutdown Application Catalog takes longer to restart than a Paused Application Catalog. |
Run/Restart |
Click to initiate execution of Jobs from a selected Application Catalog that was Paused or Shutdown. |
When you select an Application Catalog, an icon is displayed to indicate its status:
Icon |
Status |
|
All Pending Jobs and any future Jobs sent from this Application Catalog will be executed. |
|
The Pending Jobs from this Application Catalog will not be executed until the connection is restarted by clicking the Run/Start button. |
|
No Jobs from this Application Catalog will be executed until the Application Catalog is restarted by clicking the Run/Start button. All Jobs from this Application Catalog that were in Pending status when it was shutdown were Failed and must be resubmitted to execute. |